American Journal of PharmTech Research

Keyword

QC

Explore 2 research publications tagged with this keyword

2Publications
4Authors
2Years

Publications Tagged with "QC"

2 publications found

2023

1 publication

Quality Control in Mammography; An Assessment of System's Performance of 3D Breast Tomosynthesis

Mohammed A. Alnafea and Reem M. Alharbi
8/1/2023

Breast tomosynthesis has become a well-established imaging technique for clinical assessment of breast cancer. This Tree-Dimensions (3D) imaging technique is one of a major recently used method for early breast cancer detection particularly for women with a dense breast. It can also aid in the clarifying of a breast cancer diagnosis, whether by initial screening or following up after a suspicious area in the breast has been found. The image of such technique must have an optimal contrast to display mass densities and speculated fibrous structures, in order to diagnose breast cancer accurately at the earliest feasible stage. Furthermore, the spatial resolution must be sufficient to reveal the size and form of micro calcifications. To improve the accuracy of imaging diagnosis system, an effective Quality Control (QC) program can be implemented to optimize the accurate diagnosis of mammographic imaging. The main aim of this study is to evaluate the QC of 3D Tomosynthesis system, including Kilo voltages peak (kVp) accuracy, mAs linearity, Half Value Layer (HVL), Automatic Exposure Control (AEC), radiation output and mean glandular dose (MGD). Image quality assessment also included to check of spatial resolution, Signal to Noise Ratio (SNR) and Contrast to Noise Ratio (CNR). Accreditation phantoms have been used during the study. This study reveals that international standard guidelines which contain basic requirements for QC are obtained.

2022

1 publication

Performance Assessment of a Digital X-ray Unit in a Private Medical Complex in Riyadh.

Alnafea MA and Almegren SA
12/1/2022

Digital radiography allows the user to replace film-screen systems without the need to replace other parts of the X-ray system. The aim of this work is to ensure that radiology facility produces consistently high-quality images with minimum radiation doses to the patients and workers. This is achieved by planning a systematic Quality Assurance (QA) program. A number of Quality Control (QC) tests were performed consisting of a series of standardized procedures developed to detect changes in X-ray equipment's functions from its original level of performance. Four QC tests were acquired and analyzed. The first one is tube voltage, exposure, exposure time reproducibility tests. The main objective of this multi test is to investigate the ability of radiographic unit to produce the same exposure even though in short intervals. Secondly, tube voltage accuracy and kVp accuracy is maintained to ensure that the desired technique is coming out of the tube. After that mAs linearity which is the ability of radiographic unit to produce a constant radiation output for various combinations of mA and exposure time. The forth test is Half Value Layer (HVL) which is the amount of absorbing material that will reduce the intensity of the primary beam to one-half its original value. Finally the image the image quality is also assessed. The digital X-ray machine namely (Siemens 4803404X1953) successfully pass all the QC tests. In other word the calibration establishment accuracy confirm that, the X-Ray machine result is pass. This comply with the Saudi Food and Drug Authority (KSA-SFDA) that covered all medical regulatory aspects of ionizing radiation of diagnostic X-ray facilities for all practices requirements. The obtained results were performed according to the results and recommendations of the AAPM and ICRP103.

Keyword Statistics
Total Publications:2
Years Active:2
Latest Publication:2023
Contributing Authors:4
Whatsapp