mail
editor@ajptr.com
whatsapp
9409046853
logo

American Journal of PharmTech Research

Patel Satish A

Author Profile
Department of Pharmaceutical Quality Assurance, S. K. Patel College of Pharmaceutical Education and Research, Ganpat University, Ganpat Vidyanagar - 384012, Mehsana, Gujarat, India.
2
Publications
2
Years Active
3
Collaborators
63
Citations

Publications by Patel Satish A

2 publications found • Active 2011-2014

2014

1 publication

Development and Validation of Reverse Phase High Performance Liquid Chromatographic Method for Determination of Valsartan and Hydrocholorothiazide in Combined Dosage Forms

with Gandhi Jimmy M
12/1/2014

A simple, specific, accurate and precise reverse phase high performance liquid chromatographic (RP-HPLC) method was developed with high sensitivity for determination of Valsartan and Hydrochlorothiazide drugs in combined dosage forms. The separation was achieved on Zorbax CN (25 cm x 4.6 mm, 5 µm) at flow rate of 1.8 ml/min with 70: 30 mixture of phosphate buffer: acetonitrile (pH 6) as the mobile phase. The quantification was achieved with PDA detector at 265 nm. The injection volume was 20 μl. The retention times of Valsartan and Hydrochlorothiazide were 6.04 min and 2.27 min, respectively. The method was validated for linearity, precision, specificity, robustness and recovery according to the ICH guidelines. The linearity of response for Valsartan and Hydrochlorothiazide were assessed by analysis of five independent levels of calibration curve in range of 20-100 µg/ml and 2-10 µg/ml respectively. The recovery data was between 98.77-99.73% and 98.75-100.56% for Valsartan and Hydrochlorothiazide respectively. The limit of detection and quantification for Valsartan were 0.98 and 2.97μg/ml respectively and for Hydrochlorothiazide were 0.18 and 0.57μg/ml, respectively. The method was found to be simple and highly sensitive and can be useful in the routine quality control of Valsartan and Hydrochlorothiazide in bulk manufacturing and pharmaceutical dosage forms.

2011

1 publication

DEVELOPMENT AND VALIDATION OF RP-HPLC METHOD FOR SIMULTANEOUS DETERMINATION OF DIAZEPAM AND PROPRANOLOL HYDROCHLORIDE IN TABLETS

with Patel Paresh U, Patel Shweta M
12/1/2011

  A simple, specific, accurate and precise reverse phase high performance liquid chromatographic method was developed for simultaneous estimation of diazepam and propranolol hydrochloride in pharmaceutical tablet formulation. The separation was achieved on Phenomenex C18 column (250 mm i.d., 4.6 mm, 5 µm particle size) using methanol: acetonitrile: water (50 : 25 : 25, v/v/v, pH adjusted to 2.8 ± 0.05 with ortho- phosphoric acid) as the mobile phase at a flow rate of 1.0 ml min-1. The quantification was achieved with PDA detector at 235 nm. The injection volume was 20 µl. The retention times of diazepam and propranolol hydrochloride were 5.38 ± 0.29 min and 3.80 ± 0.15 min, respectively. The method was validated for linearity, precision, specificity, robustness and recovery according to the ICH guidelines. The linearity was obtained in the concentration range of 0.1-5.0 µg/ml for both drugs with mean recovery of 100.3 ± 0.47 and 100.2 ± 0.78 % for diazepam and propranolol hydrochloride, respectively. The limit of detection and quantification for diazepam were 0.015 and 0.050 µg/ml, respectively and for propranolol hydrochloride were 0.014 and 0.045 µg/ml, respectively. The method was found to be simple and highly sensitive and can be useful in the routine quality control of diazepam and propranolol hydrochloride in bulk manufacturing and pharmaceutical dosage forms.   Key words: Diazepam, propranolol hydrochloride, RP-HPLC, validation, simultaneous, tablet

Author Statistics
Total Publications:2
Years Active:2
First Publication:2011
Latest Publication:2014
Collaborators:3
Citations:63
Whatsapp