Mariyam Akter
Publications by Mariyam Akter
2 publications found • Active 2016-2016
2016
2 publicationsDevelopment and Validation of RP-HPLC Method for Simultaneous Determination of Ranolazine In Bulk and Pharmaceutical Dosage Form
This present study was undertaken with an objective to develop & validate a simple, precise, cost effective, sensitive & fast RP- HPLC method for the analysis of Ranolazine. A Shimazu HPLC system with Luna 5µm C18 is employed for the analysis using Methanol: Acetonitrile(50:50, v/v) as mobile phase. Signal from Ranolazine is detected at 227nm by UV Spectrophotometer. The total retention time was 5 min with a flow rate of 1.0 ml/min. % 0f RSD values for precision is found to be 0.798%.The limits of detection (LOD) and quantification (LOQ) were 0.616 and 1.86, respectively. As per ICH guidelines the proposed method is fully validated and found to be linear over a workable drug concentration, accurate, precise and robust. This fast, simple and inexpensive method is suitable for research laboratories & also for quality control analysis in pharmaceutical industries.
Method Validation and Development of RP-HPLC Method of Mebhydroline Napadisylate in Bulk and its Tablet Dosage Form
An accurate, simple, rapid and sensitive HPLC method has been developed for the determination of mebhydroline napadisylate in the tablet. The Chromatography was performed on a reversed phase C-18 column(150 mm × 4.6 mm id, 5μm) by isocratic elution, using a mobile phase of acetonitrile : ammonia 25% (80 : 20 v/v) at ambient temperature 25±5 °C and UV detection operates at 320 nm in an overall analysis time of about 10 min.The total retention time was 1.612 min with a flow rate of 1.0 ml/min. % 0f RSD values for precision is found to be 0.293 (< 2).The limits of detection (LOD) and quantification (LOQ) were 0.03µg/ml and 0.096133µg/ml, respectively. The correlation coefficient for Mebhydroline Napadisylate 0.9972 indicates linearity of the methods within the limits. The linear range of determination for Mebhydroline Napadisylate was 100-500μg/ml. However, the change in flow rate and column temperature also did not show any significant variance. The % recovery was found to be 99.70%-99.41%. As per ICH guidelines the proposed method is fully validated and found to be linear over a workable drug concentration, accurate, precise and robust. This HPLC method is selective, precise, and accurate and can be used for routine analysis of pharmaceutical preparation in industrial quality-control laboratories.