Development and Validation of RP-HPLC Method for Simultaneous Determination of Ranolazine In Bulk and Pharmaceutical Dosage Form

with Farhana Sharmin, Mariyam Akter
12/1/2016

This present study was undertaken with an objective to develop & validate a simple, precise, cost effective, sensitive & fast RP- HPLC method for the analysis of Ranolazine. A Shimazu HPLC system with Luna 5µm C18 is employed for the analysis using Methanol: Acetonitrile(50:50, v/v) as mobile phase. Signal from Ranolazine is detected at 227nm by UV Spectrophotometer. The total retention time was 5 min with a flow rate of 1.0 ml/min. % 0f RSD values for precision is found to be 0.798%.The limits of detection (LOD) and quantification (LOQ) were 0.616 and 1.86, respectively. As per ICH guidelines the proposed method is fully validated and found to be linear over a workable drug concentration, accurate, precise and robust. This fast, simple and inexpensive method is suitable for research laboratories & also for quality control analysis in pharmaceutical industries.

Method Validation and Development of RP-HPLC Method of Mebhydroline Napadisylate in Bulk and its Tablet Dosage Form

with Rafat Jahan, Mariyam Akter, Irin Binta Altaf
12/1/2016

An accurate, simple, rapid and sensitive HPLC method has been developed for the determination of mebhydroline napadisylate in the tablet. The Chromatography was performed on a reversed phase C-18 column(150 mm × 4.6 mm id, 5μm) by isocratic elution, using a mobile phase of acetonitrile : ammonia 25% (80 : 20 v/v) at ambient temperature 25±5 °C and UV detection operates at 320 nm in an overall analysis time of about 10 min.The total retention time was 1.612 min with a flow rate of 1.0 ml/min. % 0f RSD values for precision is found to be 0.293 (< 2).The limits of detection (LOD) and quantification (LOQ) were 0.03µg/ml and 0.096133µg/ml, respectively. The correlation coefficient for Mebhydroline Napadisylate 0.9972 indicates linearity of the methods within the limits. The linear range of determination for Mebhydroline Napadisylate was 100-500μg/ml. However, the change in flow rate and column temperature also did not show any significant variance. The % recovery was found to be 99.70%-99.41%.  As per ICH guidelines the proposed method is fully validated and found to be linear over a workable drug concentration, accurate, precise and robust.  This HPLC method is selective, precise, and accurate and can be used for routine analysis of pharmaceutical preparation in industrial quality-control laboratories.