mail
editor@ajptr.com
whatsapp
9409046853
logo

American Journal of PharmTech Research

Challa Sudheer

Author Profile
Department of Chemistry. Acharya Nagarjuna University, Nagarjunanagar, Guntur (AP) India.
2
Publications
1
Years Active
5
Collaborators
23
Citations

Publications by Challa Sudheer

2 publications found • Active 2016-2016

2016

2 publications

Method Development and Validation for Simultaneous Estimation of Ofloxacin and Ornidazole In Bulk and Pharmaceutical Dosage forms

with B .Tirumaleswara Rao, S. Madhavi, C. Rambabu
4/1/2016

A simple, rapid, sensitive reverse-phase high-performance liquid chromatography method was developed and validated for simultaneous estimation of ofloxacin and ornidazole, at single wavelength of 343nm.chromotographic separation was performed on an enable aligent zorabax(thermo) column(250nmx4.6mm ID particle size 5 um) and a  mobile phase consisting of acetonitrile and buffer (600:4300v/v) at a flow rate of 1.0ml/min. the calibration curve was linear(r2≥0.0999) over the concentration range. 400-1200μg/mL of ofloxacin and 1000-3000μg/mL of ornidazole. the limit of detection 0.00246µg/ml  for ofloxacin  0.00508µg/ml for ornidazole and no interference was found by the excipients in the synthetic mixture. The proposed methods were validated for international conference on harmonization guideline for linearity, accuracy, precision, and robustness for estimation of ofloxacin and ornidazole in bulk and synthetic mixture, and The results were found to be satisfactory

Method Development and Validation for Simultaneous Estimation of cefixime And Linezolid In Bulk and Pharmaceutical Dosage Forms

with B Tirumaleswara Rao, S. Madhavi1 C.Rambabu
4/1/2016

A simple, rapid, sensitive reverse-phase high-performance liquid chromatography method was developed and validated for simultaneous estimation of Cefixime and linezolid ,at single wavelength of 263nm.chromotographic separation was performed on an enable aligent zorabax(thermo) column(250nmx4.6mm ID particle size 5 um) and a  mobile phase consisting of acetonitrile and water(70:30v/v) at a flow rate of 1.0ml/min. the calibration curve was linear(r2≥0.0999) over the concentration range. 400-1200μg/mL of cefixime and 1200-3600μg/mL of linezolid. the limit of quantification was 9.709µg/ml for Cefixime and  9.482µg/ml  for linezolid no interference was found by the excipients in the synthetic mixture. The proposed methods were validated for international conference on harmonization guidelines for linearity, accuracy, precision, and robustness for estimation of Cefixime and linezolid in bulk and synthetic mixture, and the results were found to be satisfactory

Author Statistics
Total Publications:2
Years Active:1
First Publication:2016
Latest Publication:2016
Collaborators:5
Citations:23
Whatsapp