Published
Quality Control measurements for general X-Ray machine through X-ray meter
Published in August 2023 Issue 4 (Vol. 13, Issue 4, 2023)

Abstract
The aim of a quality assurance (QA) program is to assist a radio-diagnostic machine to obtaining adequate radiological quality information with a minimum of dose to the subject. An integrated part of a quality assurance program is Quality Control (QC) ascertaining quality by measurements and other procedures. QC in diagnostic radiography begins with production of predictable exposures. In this study the four tests (reproducibility, accuracy of kV, half value layer (HVL) and mAs linearity) were determined by Piranha X ray meter and were carried out for General X-Ray machine at Olaya Medical Complex. The QC tests have been carried out according to the intentional standard reports (AAPM No. 74) and National recommendations of King Abdullah City for Atomic & Renewable Energy. Various safety measures are taken by considering work personnel's safety. Thus, some QC tests were determined using the X-ray meter. For the accomplishment of this study, the tests of tube voltage accuracy and reproducibility, HVL and effective energy, air Kerma and air Kerma rate were performed, with their associated errors calculated. The obtained results were in the acceptable limits. The survey revealed that the QC program was conducted to this X-ray machine at regular intervals. Thus the calibration accuracy results Confirm that, the X-Ray E Machine Result is Pass.
Authors (2)
Mohammed A. Alnafea
View all publications →Huda H. Mujammami
View all publications →Download Article
Best for printing and citation
File size: 0.0 MB
Format: PDF
Download Article
Best for printing and citation
File size: 0.0 MB
Format: PDF
Article Information
Published in:
August 2023 Issue 4 (Vol. 13, Issue 4, 2023)- Article ID:
- AJPTR134004
- Paper ID:
- AJPTR-01-002206
- Published Date:
- 2023-08-01
Article Impact
Views:1,070
Downloads:2,483
scite_
Smart Citations
0Citing Publications
0Supporting
0Mentioning
0Contrasting
View Citations
See how this article has been cited at scite.ai
scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.
scite shows how a scientific paper has been cited by providing the context of the citation, a classification describing whether it supports, mentions, or contrasts the cited claim, and a label indicating in which section the citation was made.
How to Cite
A., M., & H., H. (2023). Quality Control measurements for general X-Ray machine through X-ray meter. American Journal of PharmTech Research, 13(4), xx-xx. DOI:https://doi.org/10.5281/zenodo.8260443
Article Actions
More from this Issue
Quality Control in Mammography; An Assessment of System's Performance of 3D Breast Tomosynthesis
Mohammed A. Alnafea, Reem...Read more →
More by These Authors
Method Development and Validation of Stability Indicating RP-HPLC Method for Simultaneous Estimation of Atazanavir and Ritonavir in Bulk and Its Pharmaceutical Formulations
2014 • Vol. 4, Issue 4
Read more →
