mail
editor@ajptr.com
whatsapp
9409046853
logo

American Journal of PharmTech Research

Published

Performance assessment of GE conventional X-ray System installed in Radiological Science Department of King Saud University

Published in April 2024 Issue 2 (Vol. 14, Issue 2, 2024)

Performance assessment of GE conventional X-ray System installed in Radiological Science Department of King Saud University - Issue cover

Abstract

As X-ray applications continue to evolve across medical disciplines, meticulous implementation of Quality Assurance (QA) protocols becomes paramount. It is the cornerstones in X-ray applications, ensuring accuracy, safety and effectiveness of diagnostic procedures. To get optimum use of medical equipment, specific performance tests must take place. The aim of this work is was to evaluate the performance of GE conventional X-ray System installed in 2007 at Radiological Science Department of King Saud University. Non-invasive auto meter used to evaluate the performance of such X-ray imaging system. The study investigates various Quality Control (QC) parameters, including milliampere-seconds (mAs) linearity, tube voltage accuracy, and exposure time reproducibility, to ensure compliance with established standards. All QC tests have done according to the intentional standard reports (AAPM No. 74) and National recommendations of King Abdullah City for Atomic & Renewable Energy. The obtained results indicate that the X-ray unit demonstrates acceptable mAs linearity, tube voltage accuracy, reproducibility and exposure time reproducibility tests and thus ensuring consistent X-ray output. All the obtained results meet the international standards. In general, the Department of Radiological Sciences adheres to strict quality control and quality assurance protocols for the department's equipment. To maintain consistency in radiation output, ensure user safety, and improve image quality in radiography. Through continuous monitoring and evaluation of equipment performance, while minimizing unnecessary radiation exposure to users.

Authors (2)

Abdulrahman Almutairi

Department of Radiological Sci...

View all publications →

Mohammed Alnafea

Department of Radiological Sci...

View all publications →

Download Article

PDF

Best for printing and citation

File size: 0.0 MB
Format: PDF

Download Article

PDF

Best for printing and citation

File size: 0.0 MB
Format: PDF

Article Information

Article ID:
AJPTR142004
Paper ID:
AJPTR-01-001960
Published Date:
2024-04-01

Article Impact

Views:2,070
Downloads:740
scite_
PlumX Metrics Badge

How to Cite

Almutairi & Alnafea (2024). Performance assessment of GE conventional X-ray System installed in Radiological Science Department of King Saud University. American Journal of PharmTech Research, 14(2), xx-xx. DOI:https://doi.org/10.5281/zenodo.11140498

Article Actions

Whatsapp