mail
editor@ajptr.com
whatsapp
9409046853
logo

American Journal of PharmTech Research

Published

Comparison between stainless steel stent and cobalt chromium stent in patient undergoing primary percutaneous coronary intervention (PCI) for coronary artery disease.

Published in October 2014 Issue 5 (Vol. 4, Issue 5, 2014)

Comparison between stainless steel stent and cobalt chromium stent in patient undergoing primary percutaneous coronary intervention (PCI) for coronary artery disease. - Issue cover

Abstract

The observational study was a retro-selective, unicenter, nonrandomized study to evaluate the clinical safety and efficacy of the stainless steel and cobalt-chromium alloy stent. Use of the cobalt-chromium alloy in place of stainless steel offers enhanced visibility and radial strength with thinner structural elements. The study enrolled 128 patients with symptomatic ischemic heart disease attributable to de novo or restenotic nonstented native lesions of a single vessel amenable to percutaneous stenting. The primary composite end point was the incidence of major adverse cardiac events (death, myocardial infarction, emergency bypass surgery, or target lesion revascularization) 365 days after PCI. The mean age of patient was 56.17 ± 10.43 years, with 50.81% and 47.36% of unstable angina patient. No difference in most clinical angiographic characteristic between two groups. At 1 month follow up there was no significant difference between two groups (p = 0.96). The individual clinical component showed no difference in occurrence of death (p = 0.29), MI (p = 0.29) and TLR (p = 0.96) at end of 6 month. At 1 year MACE occurred 8.1% in cobalt chromium group and 14.0% in stainless steel stent (p = 0.31). Rate of TLR was 0 % in cobalt chromium group and 3.5% in stainless steel stent (p = 0.14). The incidence of restenosis was 3.27 % in cobalt chromium group and 7.01% in stainless steel stent (p = 0.35).

Download Article

PDF

Best for printing and citation

File size: 0.0 MB
Format: PDF

Download Article

PDF

Best for printing and citation

File size: 0.0 MB
Format: PDF

Article Information

Article ID:
AJPTR45008
Paper ID:
AJPTR-01-000658
Published Date:
2014-10-01

Article Impact

Views:5,627
Downloads:2,169

How to Cite

Bhushan & Kumar, S. & Singh & Gupta & Arya (2014). Comparison between stainless steel stent and cobalt chromium stent in patient undergoing primary percutaneous coronary intervention (PCI) for coronary artery disease.. American Journal of PharmTech Research, 4(5), xx-xx. https://ajptr.scholarjms.com/articles/1252

Article Actions

Whatsapp